NAHAR ALRAYHAN MEDICAL SURGICAL EQUIPMENT INSTRUMENTS TRADING CO LLC

Ophthalmology Equipment

Auto Refractor / Auto Refractometer

MG-9000 TOP QUALITY AUTO REFRACTOMETER, AUTOREFRACTORS
SPECIFICATION:
Measurement RangeSphere -20d~+20d (Vd=12mm) 0.125d/0.25d Steps
Cylinder -8d~+8d 0.125d/0.25d Steps
Axis Angle 1°~180° 1°Steps
Pupillary Distance45~85mm 1mm Steps
Vertex Distance0/12/13.75/15mm
Minimum Pupil Diameter¢2.0mm
ChartAuto Fog Chart
Date Saving10 Measured Values For Both Eyes
SpecificationDisplay: 5.7″ Lcd(Color)
Print: Built-In Thermal Printer
Power Suppiy: Ac 220v ,50hz Or 110v, 60hz
Dimensions/Weight: 288(W)*500(D)*480(H) 14kg
Output:Rs-232
Power Save:5/10 Min (Selectable)

SLIT LAMP OPTICARE

Technical Data

o There are iphone or Sumsung mobile adapter optional, can take images by mobile.
o Type Parallel Galilean
o Eyepiece 12.5X
o Total Magnification 6X, 10X, 16X, 25X, 40X
o Diameter of Visual Field Φ 37, Φ 23, Φ 14, Φ 8.7, Φ 5.7mm
o Diopter Adjustment +5D–5D
o Slit Width 0mm-14mm continuously adjustable
o Slit Height 1mm-14mm continuously adjustable
o Aperture Diameter Φ 14, Φ 10, Φ 5, Φ 3, Φ 2, Φ 1, Φ 0.2mm
o Slit Angle 0° -180°
o Illumination Tilting 0° , 5° , 10° , 15° , 20°
o Filter Heat absorption, grey, redfree(green), cobalt blue
o Lamp: German OSRAM Halogen Tungsten Lamp
o Longitudinal movement: 90mm
o Lateral movement: 100mm
o Vertical movement: 30mm
o Fine base movement: 15mm
o Input Voltage 110V/220V 60/50Hz
o Input Power 60VA
o Illumination Bulb 12V/50W halogen bulb, led lamp optional
o Fixation Red LED

OPHTHALMIC OCT (OCT-500) OPTICARE

Technical Data Built-in computer
Simple, fast and easy to operate

Posterior segment OCT. The OCT is an ophthalmic optical coherence tomography scanner tailored for rapid screening of fundus diseases in outpatient clinics. It is easy to use, clear in image, smooth and delicate in operation, and equipped with professional analysis software to meet the requirements of OCT in the clinical examination and analysis of ophthalmology.

Features:

1.Compact Design: Everything is inside this compact body. No external computer is needed. Plug in the power cable, then you are ready to go.
2.PC Inside: Data acquisition and processing are accomplished by the internal computer. The data can be transported via ethernet or external harddrive. Peripheral devices, such as keyboard or printer, can be connected to the computer ports.
3.Easy Installation: No complex connection or setup. Compact body can fit in even small space.

MethodologySpectral domain OCT
Axial resolution≤ 6 µm (in tissue)
Transverse resolution≤ 20 µm (in tissue)
Scan depth≥ 6 mm
Scan speed≥ 24,000 A-scans/sec, up to 36,000 A-scans/sec
Scan modes30, Raster, Circle
Fundus imageOCT en face
Focus adjustment-150 to +150
Pupil diameter≥ 3 mm
OCT light source840 nm SLD
Optical power750 µW (at cornea)
Operation13.3”touch screen, optional external mouse or keyboard
Power supply100-240 V, 50/60 Hz
Dimensions497 mm × 395 mm × 490 mm (L× W × H)
WeightLED dot matrix
External Fixtion34 kg (75 lbs)

A/B SCAN

Ophthalmic AB Scan.AB-1000-OPTICARE
Feature:

1).12.1″ color and touch screen.
2). With the same software as Quantel, top one in China With advanced intelligent digital software and parameters of freezed and Stored images could be adjusted voluntarily.
3). Can have different results on the report according to different constants A Scan A measures data for every part of the eyeball as anterior chamber depth, lens thickness axial length and so on which are needed in ophthalmic surgeries, and calculates IOL by axial length.
4). B scanner use electromagnetic, better save B probe life. Scan B displays profile images of the eyeball clearly and directly. Scanning anatomical forms and nidi inside the eyeball, doctors can diagnose accurately for examination of cataract, vitreous body disease, ocular trauma, detachment of retina or choroid, macula disease, and intraocular tumor, etc
5). B scanner, video playback of 100 images.
6). A scanner, one group with 10 data to get average, At the same time the accuracy is 0.05mm

TECHNICAL DATA:
A Scan biometry
Probe frequency10MHz
Measuring modecontact
Measuring rangeOver 5mm-40mm
Measuring error≤±0.05mm
Measuring typeLength of optic axis , automatic calculation , result analysis auto ,
Image freezingauto+preservable, manual
Intraocular lens implantation (IOL)formulaSRK-T, SRX II, HOLLADAY, BINKHORST-II, HOFFER-Q,HAIGIS
Gain20-110dB
Time gain adjustment0-30dB
B Scan patterns
Probe frequency10MHz
Probing depth≥50mm
Axial Resolution≤0.2mm
Lateral resolution≤0.3mm
Gain adjustment20-110dB
Time gain adjustment0-30dB
Operation modeEyecup, gel, aqueous capsule
Post-processing measuring toolsArea, length, mark and annotation
Review100 images available
Size340mm*320mm*115mm
weight10kg
Power supply100-240V 50/60Hz

AUTOLENSOMETER

AUTO LENS METER OPTICARE
Features:

1.Measurement of PD, PH, and PCL (progressive channel Length).
D910 Auto Lens meter
2.New capacitive touch panel with high resolution
3.The wavelength of UV and green light can be measured simultaneously .
D910 Auto Lens meter
4. Bluetooth, RS232 serial port, USB and WIFI ,4 forms of data communication
5. Better performance .Finer marking pens and lens holder. Magnetic and stable sliding nosepiece
D910 Auto Lens meter

TECHNICAL DATA:
Sphere-25.00D-+25.OOD
Axis0°-180° (1°step)
CYLINDER0 – ±9.99D 0.01/0.12/0.25D steps
Prism Degree0 – 15D 0.01/0.12/0.25D steps
ADD0 – ±9.99D 0.01/0.12/0.25D steps
Cylinder+, +/-, –
PrismX-Y, P-B
Contact lensSoft/hard
Measuring ModeSingle/progressive/automatic recognition
Diameter of Lensφ12-φ112mm
PD40~90mm, 0.5mm steps
Speed of measurement0.1s
DisplayTFT LCD (7.0″) 640*480
PrinterThermal Printer
Dimension180(L) * 255(W) * 455 (H) mm
Package620(L) * 390(W) * 390 (H) mm
WeightAbout 12kgs
Power Supply100~240V 50~60H

OPTHALMIC VISUAL FIELD APS6000

Aps-6000cerTraditional Perimeter; LED
Specifications:

Aps-6000cerTraditional Perimeter; LED Specifications
Radius of stimulator: 300mm±5mm
1.Stimulating source of LED
2.Two visual lights: yellow and red.
3.Stimulating strength: From 0nt (0asb) to318.310nt (1000asb), have 14 degree to adjust, the error is±10%.
(1.)Error of background brightness: 4asb±10%
(2.)Light spot: Diameter is 2mm +/- 0.25mm.
(3.)The number of stimulating and the stimulating time:
A.388 spots (Red light: 61spots, yellow: 327spots);
B: stimulating retention time: 0.2s–2.0s, the program can adjust (±5%);
C: stimulating spacing interval: 0.5s –2.0s, the program can adjust (±5%);
4.Window of eye-position tracking: White-black CCD, directly tracking the testing eye;
5.The length of chin rest: up-down: 80mm±10%; right-left 115mm±10%Eye position tracking: When blinking, the system will alarm automatically.

TECHNICAL DATA:
Sphere-25.00D-+25.OOD
Axis0°-180° (1°step)
CYLINDER0 – ±9.99D 0.01/0.12/0.25D steps
Prism Degree0 – 15D 0.01/0.12/0.25D steps
ADD0 – ±9.99D 0.01/0.12/0.25D steps
Cylinder+, +/-, –
PrismX-Y, P-B
Contact lensSoft/hard
Measuring ModeSingle/progressive/automatic recognition
Diameter of Lensφ12-φ112mm
PD40~90mm, 0.5mm steps
Speed of measurement0.1s
DisplayTFT LCD (7.0″) 640*480
PrinterThermal Printer
Dimension180(L) * 255(W) * 455 (H) mm
Package620(L) * 390(W) * 390 (H) mm
WeightAbout 12kgs
Power Supply100~240V 50~60H

AUTO KERATOMETER

OPT-V018-N OPTICARE auto refractometer with keratometer
Features:

OPT-V018-N OPTICARE auto refractometer with keratometer
• Sphere -20~+20D(VD=12) 0.125D
• Step Cylinder -8~+8D 0.125D
• Step Axis 0°~180° (1°step) PD 045-88mm,1mm
• Step VD 0mm,12mm,13.75mm
• Min Pupil Size ø2.0mm
• Keratometry Radius of curvature 5.0~10mm(increment:0.01mm)
• Comal power 33.75~67.50D(when comer equivalent refractive index is 1.337)

GREEN LASER ARGON -APPASSAMI

Specifications:

• GREEN LASER PHOTO COAGULATOR FOR RETINAL DISORDERS
• PATENTED SOLID – STATE TECHNOLOGY
• EXTENDED LIFE AND EFFICIENCY
• TRUE CONTINUOUS WAVE
• TOUCH SCREEN INTERFACE
• Special Features
• Light weight and portable.
• LCD touch screen display with mounting
option on table and also on the console. • Foot switch with LED.
• Fiber connecting port is illuminated with LED.
• Metal shielded laser delivery fiber optic cable

TECHNICAL DATA:
ModelAMOGH PLUS
Treatment LaserDiode pumped, frequency doubled, true cw & solid state.
Laser Module Capacity3 Watts
Aiming Beam635 nm, Semiconductor diode laser,0 to 1 mW (variable)
Power AdjustmentVariable from 10 to 1500 mW
Electrical Requirements110V/230 VAC 50/60Hz, 2A, single phase
CoolingThermo electric cooling (peltier) and air cooled
Operation ModeRepeat pulse, single pulse, continuous mode
Touch Screen DisplayLCD screen with feather touch
Lifetime10,000 Working hours
Dimensions290(H) x 175(W) x 365(D) mm
Weight8 Kg
Power Consumption100 Watts
Pulse Duration0.01 – 10 Sec.
Pulse Interval0.01 – 10 Sec.
Treatment Laser SafetyClass IV

Contact Us

Please enable JavaScript in your browser to complete this form.
Scroll to Top